1 required equipment, 2 upgrade steps, Figure 11 – Clear-Com Eclipse-Omega User Manual
Page 24: Cpu dip switches in watchdog enabled mode, Eclipse upgrade reference manual

Eclipse Upgrade Reference Manual
Clear-Com Communication Systems
Page 24 of 155
Part Number: 810377Z Rev 6
Figure 11 -
CPU DIP Switches in Watchdog Enabled Mode
25. The card should now boot and on the LED display show “0”, indicating there is
no configuration file on the card.
When upgrading from 5.0 to 5.1 the new 5.1 application will reject the 5.0
configuration map; a new configuration map needs to be downloaded.
26. Repeat steps 6 through 23 for the second configuration card if present.
27. Reinsert the configuration cards into the matrix.
28. Proceed to serially download a basic configuration map to the cards using
ECS – This will then allow you to make any further configuration changes via
Serial Connection (See ECS programming manual for how to setup a basic
configuration).
3.7 Updating the Eclipse Configuration Card using TeraTerm
3.7.1 Required Equipment
1. PC with serial port connection or a USB port and USB to serial cable.
2. Configured and working TeraTerm installation.
3. Path
InstallCD\3rd_Party_Software\Teraterm\ttermp23.zip
4. Appropriate .4kr file for Eclipse Configuration Card application.
5. Use the Omega Boot application Code file as found on the Eclipse Installation
CD-ROM.
InstallCD\Omega-Median\710621Z – Config App\710621Z.4kr
6. Serial cable or USB to serial adaptor cable for PC to Eclipse interconnection.
3.7.2 Upgrade Steps
1. Start TeraTerm.