beautypg.com

Figure 67, Impact bounday scan in progress, Eclipse upgrade reference manual – Clear-Com Eclipse-Omega User Manual

Page 72

background image

Eclipse Upgrade Reference Manual

Clear-Com Communication Systems

Page 72 of 155

Part Number: 810377Z Rev 6

Figure 67 - IMPACT Bounday Scan in Progress

1. The full chain should be:

TDI - Router FPGA (XC2VP20) - Router FPGA Flash (XCF16P) - Fibre FPGA
(XC2VP20) - Fibre FPGA Flash (XCF16P) – TDO

2. If only the front or rear card alone is to be programmed only the first two or

last two devices of the above chain will be present.

3. The "Assign New Configuration File" dialog now is asking you to select an

FPGA image for the first device in the chain, or to bypass that device.

4. We're going to bypass the XC2VP20 (first device) and the XC2VP20 (third

device), and provide images for the second and fourth devices (the FPGA
flashes).

5. So, hit the Bypass button for the first device, select the FPGA image for the

router for the second device, Bypass the third device and select the FPGA
image for the networking FPGA.

InstallCD\Omega-Median\710793Z - Fibre Router FPGA\710793Z-PROG-
2.mcs

InstallCD\Omega-Median\710794Z - Fibre Networking FPGA\710794Z-
PROG-2.mcs

6. Once you've done all the devices, a summary dialog will be presented. For the

XCF16P device(s) (one if only doing the front or back cards, two if both)

This manual is related to the following products: