beautypg.com

Figure 66, Impact tool boundary scan, Eclipse upgrade reference manual – Clear-Com Eclipse-Omega User Manual

Page 71

background image

Eclipse Upgrade Reference Manual

Clear-Com Communication Systems

Page 71 of 155

Part Number: 810377Z Rev 6

5. Connect the 14way IDC header to CON5 of the rear card if only programming

the rear card.

6. Power up the UUT and start the iMPACT programming tool.
7. Select Cancel in the Load Project dialogue.
8. In the ‘Flows’ window, double click on ‘Boundary Scan’.

Figure 66 - IMPACT Tool Boundary Scan

9. Right click in the main window and select “Initialise Chain” / Ctrl+ I.
10. When this is done, a dialog, "Assign New Configuration File", will be

presented. Ignore this for a moment, since you need to check the device list
first.

11. If the cable is connected correctly the application will connect and a Xilink chip

chain will be shown (note: picture below does not show the correct device
chain) – else a cable connection warning will be given.