Figure 103, Programming device using flash magic, Eclipse upgrade reference manual – Clear-Com Eclipse-Omega User Manual
Page 119

Eclipse Upgrade Reference Manual
Clear-Com Communication Systems
Page 119 of 155
Part Number: 810377Z Rev 6
Figure 103 - Programming Device Using Flash Magic
6. In Box 1
- select the COM port on which you are connected
- select a Baud Rate of 2400,
- select device 89LPC935
- select Oscillator Frequency of 3.5795 MHz
7. In Box 2
- select “Erase Blocks Used By Hex File”
8. In Box 3
- Enter the name of the file (710756Z .hex) to be loaded, or use
the “browse” button to locate the file.
9. In Box 4
- ensure all boxes are clear
DO NOT PRESS “Start” YET
10. In the menu options along the top, select ISP, the second option from the left.
11. In the dropdown menu list select “Start Bootloader”, the screen should now
look like this: