As an example, the following command line…

websync –poll 10 –path C:\Logs 192.9.200.52

…will read the log files for all data logs on the terminal with the IP address of 192.9.200.52,
and will store these logs under subdirectories of the

C:\Logs

directory. WebSync will

continue to execute, and will repeat the polling process every ten minutes. The polling
interval must obviously be set such that it is much less than the sampling rate times the
number of samples in a file times the number of log files to be retained. If this constraint is
met, the directory on the PC will accumulate copies of all the log files from the terminal.