12 dsl port downstream psd command, 13 dsl port upstream carrier command, Figure 223 dsl port upstream psd command example – ZyXEL Communications IES-612-51A User Manual
Page 350: Figure 224 dsl port downstream psd command example

Chapter 52 ADSL Commands
IES-612-51A User’s Guide
350
where
This command displays or sets the upstream maximum nominal transmit PSD (Power Spectral
Density).
The following example sets the upstream maximum nominal transmit PSD for port 7 to -10
dBm/Hz.
52.1.12 DSL Port Downstream PSD Command
Syntax:
ras> adsl dsnompsd
where
This command displays or sets the downstream maximum nominal transmit PSD (Power
Spectral Density).
The following example sets the downstream maximum nominal transmit PSD for port 7 to -10
dBm/Hz.
52.1.13 DSL Port Upstream Carrier Command
Syntax:
ras> adsl uscarrier
where
psd> = -400 ~ 40 (unit of measure is 0.1dBm/Hz) Figure 223 DSL Port Upstream PSD Command Example ras> adsl usnompsd 7 -100 psd> = -400 ~ 40 (unit of measure is 0.1dBm/Hz) Figure 224 DSL Port Downstream PSD Command Example ras> adsl dsnompsd 7 -100 = The upstream subcarriers to be masked (disabled). Each = tones 0~31 = tones 32~63 The hexadecimal digit is converted to binary and a '1'
(00000000~ffffffff). Each
(each hexadecimal digit represents 4 tones).
disables the corresponding tone. Disabling a carrier tone
turns it off so the system does not send data on it.