Chapter 43 Alarm Commands

IES-612-51A User’s Guide

285

The following example displays the port alarm thresholds for all ports. “ifindex” identifies the
interface.

43.5 Alarm Port Set Command

Syntax:

ras> alarm port set

where

This command sets the alarm severity threshold for recording alarms on an individual port(s).
The system reports an alarm on a port if the alarm has a severity equal to or higher than the
port’s threshold.

The following example has the IES-612-51A only record critical alarms on DSL port 7.

43.6 Alarm Tablelist Command

Syntax:

ras> alarm tablelist [|all] [|all]

[|all][[,]] [|all]

where

Figure 139 Alarm Port Show Command Example

ras> alarm port show

no ifindex severity

----- ---------- -----------

01 01 minor

02 02 minor

03 03 minor

04 04 minor

05 05 minor

==================================== SNIP =================================

Press any key to continue, 'e' to exit, 'n' for nopause

2|port>

=

Ports on the IES-612-51A.

Figure 140 Alarm Port Set Command Example

ras> alarm port set 7 critical

=

The log facility (

local1~local7

) that has the device log

the syslog messages to different files in the syslog server.
See your syslog program’s documentation for details.

=

snmp|syslog|all

The type of alarm messages that the

device is to send (SNMP, syslog or all).