Chapter 42 Command Examples

IES-612-51A User’s Guide

281

An example is shown next.

42.4.2 Isolation Enable Command

Syntax:

ras> switch isolation enable

This command turns on the subscriber isolation feature.

42.4.3 Isolation Disable Command

Syntax:

ras> switch isolation disable

This command turns off the subscriber isolation feature.

42.5 Statistics Monitor Command

Syntax:

ras> statistics monitor

This command shows the current hardware status (voltage and temperature).

An example is shown next.

42.6 Statistics Port Command

Syntax:

ras> statistics port [ ] [clear]

Figure 135 Isolation Show Example

ras> switch isolation show

system isolation: enabled

Figure 136 Statistics Monitor Command Example

ras> statistics monitor

Hardware monitor status: enabled

nominal limit(hi) limit(lo) current min max avg status

------- --------- --------- --------- -------- -------- -------- ----

----

v1(v) 1.200 1.344 1.056 1.152 1.139 1.152 1.148 Normal

v2(v) 1.800 1.944 1.656 1.820 1.820 1.820 1.820 Normal

v3(v) 3.300 3.564 3.036 3.200 3.200 3.200 3.200 Normal

v4(v) 18.000 19.440 16.560 18.175 18.175 18.175 18.175 Normal

limit(hi) limit(lo) current min max avg status

--------- --------- --------- --------- --------- --------- --------

t1(c) 97.000 -55.000 43.000 40.000 52.000 43.000 Normal

t2(c) 97.000 -55.000 46.000 41.000 59.000 46.000 Normal

t3(c) 97.000 -55.000 47.000 42.000 58.000 47.000 Normal