Fuser unit temperature control
The heater in the fuser unit is controlled by the thermister, IOGA3 and CPU to keep the
heater roller surface within a prescribed temperature range. The CPU supervises the status
of the port PC0 periodically, turning HEATON signal on and off according to CPU of PC0
(A/D converter input section) status to exercise temperature control.
At power on time, the CPU switches the output signal THON from pin 65 (between high
and low states) to check for a blown or shorted thermister according to the status of the
THCHK signal.
A built-in thermostat in the fuser unit prevents the heater from being overheated in event of
failures in the thermister, or temperature control circuit, etc.
Figure A3.2.18 shows the fuser unit temperature control.
Note: Heater control
Temperature of the heater at the time of printing is 150 ˚C to 180 ˚C. This temperature is
maintained by controlling the on and off operation of heater according to the input of the
thermister converted into analogue-digital (A/D) values by the CPU.