Freq Std

Auto

Function Group

Menu Map

Description

Programming Codes

See Also

SYSTEM

8

This

sets the synthesizer to choose its frequency standard

automatically. If an external standard is connected to the 10 MHz
REF INPUT BNC, then it is chosen as the reference. If no external
standard is connected, the internal standard is chosen as the

reference. If the internal standard has been disconnected also, the
synthesizer operates in a free run state. An asterisk next to the key
label indicates that this feature is active.

SCPI: ROSCillator[:SOURce]:AUTO
Analyzer: NONE

Ref Osc Menu

Freq Std

Function Group

Menu Map

Description

HP 8360

User’s Handbook

SYSTEM

8

This

tells the synthesizer to accept an external 10 MHz signal

as the frequency reference. The external signal must be applied to
the 10 MHz REF INPUT BNC connector located on the rear panel.
If no external signal is applied,

UNLOCK

and

EXT REF

appears on

the message line of the display. An asterisk next to the key label
indicates that this feature is active.

Operating and Programming Reference T-l