COMMAND SUMMARY

Pulse Subsystem

Since frequency and period are inversely related, if both are sent
in the same message, only the last one is applied. If the

command and either the

or

command are sent

in the same message, they must be accepted without error if the

resulting pulse is possible.

l

PULSe:FREQuency

l

PULSe:FREQuency ?

I

Sets and queries the frequency of the internal pulse generator. The

resolution of the frequency is such that the resulting period is set to a

resolution of 1

The *RST value is 500

l

PULSe:PERiod

suffix]

l

PULSe:PERiod?

Sets and queries the period of the internal pulse generator. The

resolution of this is 1

The *RST value is 2

l

PULSe:WIDTh

l

PULSe:WIDTh?

Sets and queries the width of the internal pulse generator. The *RST

value is 1

l

PULM:SLEW

l

PULM:SLEW?

Sets and queries the rise time for the pulse modulation. The typical

usage is MAX I MIN since calibrating the rise time of the pulses is not

common. Slow pulse is set by the command PULS:SLEW MAX. Any

value above 1.8

is set to maximum. The *RST setting is

MIN.

l

PULM:SLEW:AUTO?

Sets and queries the automatic setting of rise time for the pulse

modulation system. The *RST setting is ON.

l

PULM:SOURce

l

PULM:SOURce?

Sets and queries the source for the pulse modulation control signal.

*RST value is

l

PULM:STATe

PULM:STATe?

Sets and queries the state of pulse modulation. The *RST value is 0.

l

ROSCillator:SOURce?

l

ROSCillator:SOURce

Sets and queries the reference oscillator selection switch. The

HP 8360