beautypg.com

M1--m2 sweep, Manual sweep – HP 8360 User Manual

Page 247

background image

M

Sweep

Function Group

MARKER

Menu Map

Description

This

lets you set the synthesizer to start sweeping at the

frequency of marker 1 (Ml), and stop sweeping at the frequency of
marker 2

must have a higher frequency value than Ml. If

Sweep

is activated when

is at a lower frequency than

Ml, the values of Ml and

are permanently interchanged. While

this function is active, the start/stop frequencies of the synthesizer
are changed to the values of Ml and

An asterisk next to the key

label indicates this feature is active.

Programming Codes

SCPI:

SWEep:MARKer:STATe

Analyzer:

function on, MPO function off.

See Also

Marker Ml,

“Marker Operation,” in Chapter 1.
“Programming Typical Measurements,” in Chapter 1.

Manual Sweep

Function Group

SWEEP

Menu Map

Description

This

lets you set the synthesizer to the manual sweep mode

of operation. Depending on what parameter is sweeping, you can
use either the rotary knob or the ARROW keys to manually sweep
between the start/stop limits. In manual sweep mode, the synthesizer
does not automatically retrace at the sweep end point (the user must
turn the rotary knob to retrace), and the green SWEEP LED does
not light. The resolution of the rotary knob is 0.1% of the sweep
span in either start/stop or

mode. The resolution of the

and

arrow keys are dependent on the resolution defined by

HP 8360

User’s Handbook

Operating and Programming Reference M-l