Sets and queries the manual frequency. This controls the output
frequency in swept manual mode. The limits are START and STOP.
*RST value is the same as FREQ : CENTER. See FREQ : CENTER for more
information.
l
FREQuency:MODE
l
Sets and queries the switch that selects either swept, CW or list
operation. *RST value is CW.
l
FREQuency:MULTiplier
l
FREQuency:MULTiplier?
Sets and queries the frequency multiplier. The numeric value is
rounded to the nearest integer. This function changes mapping of
frequency parameters on input to and output from the synthesizer.
Changing this does not affect the output frequency of the synthesizer.
Only the displayed parameters and query responses are changed.
The equation implied by this is :
Entered/displayed frequency = (Hardware Freq * Multiplier )
Offset
After
the value is 1.
l
FREQuency:MULTiplier:STATe
l
FREQuency:MULTiplier:STATe?
Queries and turns the frequency multiplier off and on.
After
the setting is OFF.
l
FREQuency:OFFSet
l
FREQuency:OFFSet?
Sets and queries the frequency offset. This function changes the
mapping of the frequency parameters on input to and output from
the synthesizer. Changing this does not affect the output frequency
of the synthesizer. Only the displayed parameters and query
responses are changed. The equation implied by this is :
Entered/displayed frequency = (Hardware Freq Multiplier
Offset
After
the value is 0.
l
FREQuency:OFFSet:STATe
l
FREQuency:OFFSet:STATe?
Queries and turns the frequency offset off and on.
After
the setting is OFF.
l
: SPAN
req
l
FREQuency:SPAN?
HP 8360
User’s Handbook
Operating and Programming Reference