S

Function Group

Menu Map

Description

Programming Codes

See Also

HP 8360

User’s Handbook

SYSTEM

8

This

allows up to eight different front panel settings to

be stored in memory registers 1 through 8. Synthesizer settings
can then be recalled with the

key. A memory register

can be alternated with the current front panel setting using the

Regs

The information stored in memory registers is retained in memory

indefinitely when ac line power is constantly available, or for

approximately three years without line power. Pressing

does

not erase the memory registers (1 through 8).

Register 0 is a memory register also. It saves the last front panel
settings automatically) and can not be accessed through the

key. Likewise, register 9 is reserved for user preset storage and can
not be accessed with the [SAVE) key. Pressing

erases register

0, but not register 9.

SCPI:

The above is an IEEE 488.2 common command.

Analyzer:

where

a numeric value from 1 to 8.

Regs, Clear

Memory,

Save Lock

“Saving and Recalling an Instrument State,” in Chapter 1.
“Programming Typical Measurements,” in Chapter 1.

Operating and Programming Reference S-l