ENVIRONMENTAL AND OPERATING SPECIFICATIONS

Temperature:

Operating: 4

o

C to 46

o

C

Transportation: -40

o

C to 65

o

C

Storage: -22

o

C to 60

o

C

Relative Humidity:

Operating: 20% to 80% (noncondensing).
Max. wet bulb temperature: 26

o

C

Transportation: 20% to 80% (noncondensing).
Max. wet bulb temperature: 26

o

C

Power Requirements
Voltage: 90 to 132VAC.
Frequency: 47 to 63 Hz.

Average current (in Amps) with drives operating:

1 Floppy

2 Floppies

1 Floppy, 1 Hard

Typical unit:

0.32A

0.34A

0.35A

Maximum:

0.32A

0.46A

0.47A

Power consumption (maximum):

1 Floppy

2 Floppies

1 Floppy, 1 Hard

Floppies not operating: 38 watts

41 watts

42 watts

Floppies Operating:

52 watts

55 watts

56 watts

Dimensions (WxHxD): 12-1/2" x 3-1/2" x 9-1/2"

Weight:

1 floppy drive

8.5 pounds

2 floppy drives 9.5 pounds
1 floppy, 1 hard 9.7 pounds

Component Life:

5 years

Safety Standard:

UL

FILTER MAINTENANCE

The Site Controller II comes equipped with an air filter on the fan intake. A properly functioning
filter should help reduce problems with the floppy disk drives; a clogged filter may cause harm to
the site controller due to restricted air flow. It is strongly recommended that the filter element be
cleaned at least once a month in dusty environments. DO NOT install this filter element unless
you plan to adhere to the recommended cleaning schedule.

To remove the filter for cleaning: Make sure no transaction is in progress. Turn off the site
controller and wait until the fan comes to a stop. Snap off the black plastic filter cover by pulling it
straight back. Remove the foam filter and clean in warm soapy water. Rinse thoroughly and pat
dry. Re-install filter and replace filter cover. Re-start the site.