Environmental and operating specifications, Filter maintenance – Gasboy CFN Series Diagnostic Manual User Manual
Page 70
GASBOY CFN Series
3-6
03/19/04
ENVIRONMENTAL AND OPERATING SPECIFICATIONS
Temperature:
Operating: 4
o
C to 46
o
C
Transportation: -40
o
C to 65
o
C
Storage: -22
o
C to 60
o
C
Relative Humidity:
Operating: 20% to 80% (noncondensing).
Max. wet bulb temperature: 26
o
C
Transportation: 20% to 80% (noncondensing).
Max. wet bulb temperature: 26
o
C
Power Requirements
Voltage: 90 to 132VAC.
Frequency: 47 to 63 Hz.
Average current (in Amps) with drives operating:
1 Floppy
2 Floppies
1 Floppy, 1 Hard
Typical unit:
0.32A
0.34A
0.35A
Maximum:
0.32A
0.46A
0.47A
Power consumption (maximum):
1 Floppy
2 Floppies
1 Floppy, 1 Hard
Floppies not operating: 38 watts
41 watts
42 watts
Floppies Operating:
52 watts
55 watts
56 watts
Dimensions (WxHxD): 12-1/2" x 3-1/2" x 9-1/2"
Weight:
1 floppy drive
8.5 pounds
2 floppy drives 9.5 pounds
1 floppy, 1 hard 9.7 pounds
Component Life:
5 years
Safety Standard:
UL
FILTER MAINTENANCE
The Site Controller II comes equipped with an air filter on the fan intake. A properly functioning
filter should help reduce problems with the floppy disk drives; a clogged filter may cause harm to
the site controller due to restricted air flow. It is strongly recommended that the filter element be
cleaned at least once a month in dusty environments. DO NOT install this filter element unless
you plan to adhere to the recommended cleaning schedule.
To remove the filter for cleaning: Make sure no transaction is in progress. Turn off the site
controller and wait until the fan comes to a stop. Snap off the black plastic filter cover by pulling it
straight back. Remove the foam filter and clean in warm soapy water. Rinse thoroughly and pat
dry. Re-install filter and replace filter cover. Re-start the site.