Environmental and operating specifications, Wiring – Gasboy CFN Series Diagnostic Manual User Manual
Page 379
CFN Islander
12/26/02
13-11
ENVIRONMENTAL AND OPERATING SPECIFICATIONS
Temperature:
Operating: -40
o
C to 50
o
C
Transportation: -15
o
C to 60
o
C
Storage: -15
o
C to 60
o
C
Relative Humidity:
Operating: 2% to 99% (noncondensing).
Max. wet bulb temperature: 26
o
C
Transportation: 2% to 99% (noncondensing).
Max. wet bulb temperature: 26
o
C
Power Requirements:
Voltage: 90 to 132VAC.
Frequency: 47 to 63 Hz.
Power Ratings:
Model
VA Max. at 120 VAC
Model
VA Max. at 120 VAC
ISL -
120
ISL - 4HS
135
ISL - S
115
ISL - 4HP
220
ISL - SG
115
ISL - 4HPS
215
ISL - P
200
ISL - 8H
150
ISL - SP
195
ISL - 8HS
145
ISL - 4H
140
NOTE: Add 10VA to reading above for units with –2 suffix. Not applicable for units with –S
option.
Safety Standard:
UL
WIRING
All field wiring connections are made to the Islander via terminal block. The Islander wiring is split
into two classifications, AC and DC. Separate conduits must be provided for each. AC and DC
wiring must never be mixed in any common junction box, conduit, or trough (see CFN Islander I
or Islander II Installation Manual for detailed instructions). The following tables list the
connections that can be found in the Installation Manual.
Connectors
AC Power – TB2
Pinout
Pin
Function
Voltage
H
AC hot input
115 VAC
N
AC neutral input
AC neutral
G
AC ground input
AC ground
RS-232 Data Terminal Communications Local Port – TB3
RS-232 General Purpose Communications Port 1 – TB5 or Port 3 – TB6 (Islander II only)
Pinout
Pin
Function
Input/Output
1
TxD – Transmit data
Output
2
DTR – Data terminal ready
Output
3
RxD – Receive data
Input
4
CD – Carrier Detect
Input
5
Signal ground
Ground