background image

CFN Islander

12/26/02

13-11

ENVIRONMENTAL AND OPERATING SPECIFICATIONS

Temperature:

Operating: -40

o

C to 50

o

C

Transportation: -15

o

C to 60

o

C

Storage: -15

o

C to 60

o

C

Relative Humidity:

Operating: 2% to 99% (noncondensing).
Max. wet bulb temperature: 26

o

C

Transportation: 2% to 99% (noncondensing).
Max. wet bulb temperature: 26

o

C

Power Requirements:

Voltage: 90 to 132VAC.
Frequency: 47 to 63 Hz.

Power Ratings:
Model

VA Max. at 120 VAC

Model

VA Max. at 120 VAC

ISL -

120

ISL - 4HS

135

ISL - S

115

ISL - 4HP

220

ISL - SG

115

ISL - 4HPS

215

ISL - P

200

ISL - 8H

150

ISL - SP

195

ISL - 8HS

145

ISL - 4H

140

NOTE: Add 10VA to reading above for units with –2 suffix. Not applicable for units with –S
option.

Safety Standard:

UL

WIRING

All field wiring connections are made to the Islander via terminal block. The Islander wiring is split
into two classifications, AC and DC. Separate conduits must be provided for each. AC and DC
wiring must never be mixed in any common junction box, conduit, or trough (see CFN Islander I
or Islander II Installation Manual
for detailed instructions). The following tables list the
connections that can be found in the Installation Manual.

Connectors
AC Power – TB2

Pinout

Pin

Function

Voltage

H

AC hot input

115 VAC

N

AC neutral input

AC neutral

G

AC ground input

AC ground

RS-232 Data Terminal Communications Local Port – TB3
RS-232 General Purpose Communications Port 1 – TB5 or Port 3 – TB6 (Islander II only)

Pinout

Pin

Function

Input/Output

1

TxD – Transmit data

Output

2

DTR – Data terminal ready

Output

3

RxD – Receive data

Input

4

CD – Carrier Detect

Input

5

Signal ground

Ground