Site controller iii comm. (cpu) pcb (c05838) – Gasboy CFN Series Diagnostic Manual User Manual
Page 340

Site Controller III
12-6
1116
SITE CONTROLLER III COMM. (CPU) PCB (C05838)
The CPU PCB for the Site Controller III (C05838) controls all activity in the site controller. The
CPU PCB:
•
processes all site controller data
•
provides an interface to the PC
•
communicates to all CFN equipment via the RS-485 lines
•
communicates on five RS-232 ports
•
controls the Memory I/O PCB
•
communicates to Tokheim Pumps via the Memory I/O PCB dual Tokheim port
•
provides diagnostic LED's
•
requires OS version 3.0A or greater
•
requires Memory PCB C05839
•
requires DSite 1.0C or higher
Layout
LED Indicators
LED indicators are provided to allow you to monitor the CPU's operation.
PCB Functions
LED
Color
Function
Status
DS1
Red
Network Poll
Flashes–Polled by online network
DS2
Red
CFN Poll
Flashes–Polled by CFN host
DS3
Red
ICR or FPR Poll
Flashes–Polling ICR or FPR
DS4
Red
PCU Poll
Flashes–Polling PCU
DS5
Red
Console Poll
Flashes–Polling console
DS6
Red
Foreground Task
Flashes once per second
DS7
Red
Checksum Complete
Flashes when checksum is complete