GASBOY CFN Series

4-46

03/19/04

ICR Responds incorrectly to cards. BAD CARD, READ ERROR, or no response at all
occurs.

Possible Cause

Checks

Corrective Action

K Jumpers and dipswitches
are set incorrectly.

Check K jumpers and
dipswitch settings on the
reader terminal CPU board for
proper settings.

Correct settings of K jumpers
and dipswitches if they are
wrong.

Card reader is dirty.

None.

Use a GASBOY head cleaning
card to clean the magnetic
head or optical reader glass.

Phone cable not connected to
correct communications port.

Check that the phone cable is
connected to LOOP 1 ISLAND
on the SC II or PCU/RT Port
on the SC I.

Install phone cable in correct
port.

For Magnetic Reader Only

Possible Cause

Checks

Corrective Action

Card is defective.

Run self-test # 7.

Try cards that you know are
good. If the new cards work,
the original card is bad and
should be discarded.

Defective magnetic reader.

Run self-test # 7.

If problem still occurs when
card is entered, replace
magnetic card reader.

Defective Reader Terminal
CPU board.

Run self-test # 7.

If problem still occurs when
card is entered, replace
Reader Terminal CPU board if
replacing magnetic card
reader did not correct problem.