GASBOY CFN Series
4-18
03/19/04
NOVA.HEX Software (C05375 only)
NOVA.GATE or STAR.GATE Software (C05375 only)
DEAD
This switch enables the deadman timer. It should always be open.
DPT
This switch enables the decimal point on the keypad. Closing the switch causes the decimal point
to act as a CLEAR key.
DES
When open, the PIN number entered with a bank card transaction is encrypted before it is sent to
the site controller.
INSRT
This switch should be closed when a swipe mag card reader or optical reader is used and open for
a insertion type mag card reader.
CRC
(NOVA.HEX only) This switch should always be open to allow data integrity checks to be
performed on the data going between the ICR and the site controller.
GATE
(NOVA.GATE or STAR.GATE only) This switch should always be open when used as an island
card reader and closed when used as a gate controller.
OPT
This switch should be closed for a mag card reader and open for an optical reader.
ICR 2 Software (C05857 only)
DPT
Open, enables decimal point on the keypad. Closed, the decimal point acts as a CLEAR key.
DIS
Open, 2 lines of the display are displayed; Closed, only 1 line is displayed.
INSRT
Open for an insertion mag card reader or card/key combination; closed for a swipe mag card
reader/key reader.
GATE
Always open for an island card/key reader; always closed for a gate controller.
OPT
Open for an optical reader; closed for a mag card/key reader.