GASBOY CFN Series

10-4

0021

Console doesn't sense cash drawer closure.

Possible Cause

Checks

Corrective Action

Defective cash drawer.

Measure between the COM
(DC ground) post of the
Console power supply and pin
5 (green wire) of P6 on the
Console CPU board.

Replace the cash drawer if
the signal at pin 5 of P6
doesn't go from +5VDC
(drawer open) to 0VDC
(drawer closed)

Improper switch setting on
Console II CPU board. Skip
this part if you have a
Console I.

Check position of SW2-6

Close SW2-6 and press reset
switch SW1 on the Console
CPU board

Defective Console CPU
board.

None.

Replace the Console CPU
board if cash drawer closure
is still not sensed