Site Controller III
1116
12-5
RS-485 - Loop 1 Island Communications
Pinout
Pin
Function
Voltage
1
RS-485 Rx+
2
RS-485 Rx-
From
Island Loop
+5 VDC signal
between pins 1 & 2
3
RS-485 Tx+
4
RS-485 Tx-
To
Island Loop
+5 VDC signal
between pins 3 & 4
RS-485 - Loop 2 Island Communications (Usually to Tokheim DPTs)
Pinout
Pin
Function
Voltage
1
RS-485 Rx+
2
RS-485 Rx-
From
Island Loop
+5 VDC signal
between pins 1 & 2
3
RS-485 Tx+
4
RS-485 Tx-
To
Island Loop
+5 VDC signal
between pins 3 & 4
RS-485 - Loop 3 Console Communications
Pinout
Pin
Function
Voltage
1
RS-485 Rx+
2
RS-485 Rx-
From
Console Loop
+5 VDC signal
between pins 1 & 2
3
RS-485 Tx+
4
RS-485 Tx-
To
Console Loop
+5 VDC signal
between pins 3 & 4
Dual Tokheim Pump Communications Port 3
Pinout
Pin
Function
Input/Output
1,8
Not connected
2
TTDA – Talk to Dispenser, Channel 1
Output
3
TTCA – Talk to Console, Channel 1
Input
4
TTDB – Talk to Dispenser, Channel 2
Output
5
TTCB – Talk to Console, Channel 2
Input
6,7,9
Signal ground
Ground