Site Controller III

12-4

1116

WIRING

All field wiring is made to the unit by plug-in connectors. PC peripherals (monitor, mouse, etc.)
are connected per the manufacturer's instructions. The AC power for the unit comes from the AC
power plug. The RS-485 communication comes through the modular cable that is connected to
the RS-485 junction box. Communication to the Checkpoint console or Profit Point goes through
the RS-485 connector designated loop 3 POS high speed. See the CFN SC III Installation Manual
for detailed wiring instructions.

Connectors
AC Power

Pinout

Pin

Function

Voltage

H

AC hot input

115 VAC

N

AC neutral input

AC neutral

G

AC ground input

AC ground

RS-232 - General Purpose Communications Port 1

Pinout

Pin

Function

Input/Output

1

DTR – Data terminal ready

Output

2

CTS – Clear to send

Input

3

TxD – Transmit data

Output

4

Signal ground

Ground

5

RxD – Receive data

Input

6,7,8

Not connected

RS-232 - General Purpose Communications Ports 4, 5, and 6

Pinout

Pin

Function

Input/Output

1

DTR – Data terminal ready

Output

2

CTS – Clear to send

Input

3

TxD – Transmit data

Output

4

Signal ground

Ground

5

RxD – Receive data

Input

6

DSR – Data set ready

Input

7

RTS – Request to send

Output

8

DCD – Carrier Detect

Input