Wiring, Ac power, Rs-232 - general purpose communications port 1 – Gasboy CFN Series Diagnostic Manual User Manual
Page 338

Site Controller III
12-4
1116
WIRING
All field wiring is made to the unit by plug-in connectors. PC peripherals (monitor, mouse, etc.)
are connected per the manufacturer's instructions. The AC power for the unit comes from the AC
power plug. The RS-485 communication comes through the modular cable that is connected to
the RS-485 junction box. Communication to the Checkpoint console or Profit Point goes through
the RS-485 connector designated loop 3 POS high speed. See the CFN SC III Installation Manual
for detailed wiring instructions.
Connectors
AC Power
Pinout
Pin
Function
Voltage
H
AC hot input
115 VAC
N
AC neutral input
AC neutral
G
AC ground input
AC ground
RS-232 - General Purpose Communications Port 1
Pinout
Pin
Function
Input/Output
1
DTR – Data terminal ready
Output
2
CTS – Clear to send
Input
3
TxD – Transmit data
Output
4
Signal ground
Ground
5
RxD – Receive data
Input
6,7,8
Not connected
RS-232 - General Purpose Communications Ports 4, 5, and 6
Pinout
Pin
Function
Input/Output
1
DTR – Data terminal ready
Output
2
CTS – Clear to send
Input
3
TxD – Transmit data
Output
4
Signal ground
Ground
5
RxD – Receive data
Input
6
DSR – Data set ready
Input
7
RTS – Request to send
Output
8
DCD – Carrier Detect
Input