beautypg.com

Gasboy CFN Series Diagnostic Manual User Manual

Page 422

background image

CFN Islander

13-54

12/26/02

Printout shows one or more files reconstructed – Islander with C06731 Memory Board

Possible Cause

Checks

Corrective Action

Switch SW1 positions 1 & 2
are open and power was off.

Check switch position.

Close position 1. If LED 4 is
on, open position 1 and close
2.

Batteries not installed.

Check to see if B1 and B2 are
in sockets.

Defective battery may have
been removed and not
replaced. Install new
batteries if needed.

Incorrect memory board
jumper or switch settings.

Check K1-K6 and SW1 for
proper settings.

Install the jumpers or set
switches correctly if they are
wrong.

Batter failure while power was
off.

Check if the red battery
failure LED is on.

Go to battery failure problem.

Defective memory board.

None.

Replace the memory board if
the files continue to be
reconstructed.