OUT OF SERVICE is displayed on console.

Possible Cause

Checks

Corrective Action

Site controller not running.

Check that site controller is
functioning properly.

If not, go to the Problems
section of Section 2 or 3
depending on your site
controller

Console not configured at the
site controller.

Do a PRint DIagnostics
command at the site
controller.

If the console doesn't show
up in the PRint DIagnostics
command, you must add it to
the configuration.

For SC II, use the Table
program to add the console.
For SC I, the CONFIG
locations are Table 18, offset
96 for initial number of
consoles and Table 18,
offsets 98 and 99 for
maximum number of
consoles.

Incompatible software
between the site controller
and console.

If any software was just
changed, call GASBOY
Technical Service to verify
software compatibility.

Replace software if instructed
to do so.

Console not enabled from site
controller.

Do a PRint DIagnostics
command at the site
controller.

If the printout reports Console
Went Down, Never Came Up,
or was Disabled by
Command, do an ENable
CONsole x command, where
x is the console address

RS-422 phone cable not
connected to correct
communications port.

Check that the phone cable is
connected to CONSOLE on
the SC I.

Install phone cable in correct
port.

Incorrect switch settings on
Console CPU board.
(Console I, IA, and II).

Check the SW2 and SW3
switches on the Console CPU
board.

Correct the switch settings, if
necessary.

(Continued)