beautypg.com

Sw3 - baud rate switches, Miscellaneous switches – Gasboy CFN Series Diagnostic Manual User Manual

Page 37

background image

Site Controller I

0021

2-11

SW3 - Baud Rate Switches

Miscellaneous Switches

Some of these switches work in conjunction with the position of the Manager's keyswitch. See
Manager's Keyswitch on the next page.

DEBUG

This switch is used to put the unit in debug mode. When closed the unit will run in
debug. The switch should normally be set in the open position for normal run mode.

PULSE

This switch (used in conjunction with SW5) is used to disable the system's ability to
change the pump type and pulser divisor. When this switch is open and SW5 is to
the right (when looking at the rear of the unit), you can change the pump type and
pulser divisor.

SIGN-ON

This switch controls the type of sign-on needed to log-on to the system. When open,
the sign-on loaded with the LOAD SIGNON command is used. When closed, the
sign-on configured in the personality EEROM (default sign-on) is used.

CONFIG

This switch controls the system's ability to write to (configure) the personality
EEROM. When closed, personality EEROM changes can be made. When open,
they cannot. Attempting to write changes to the personality EEROM while this
switch is open, will result in WRITE ERROR messages displayed on the terminal.