Gasboy CFN Series Diagnostic Manual User Manual
Page 253
Postpay-Prepay Console
1310
7-17
SW2 & SW3 - Miscellaneous Switches P-P II
DECP For switch 2-1. In the open position, the display omits the decimal point in the dollars
display and up to 8 digits can be entered. This is to accommodate the Mexican peso. In
the closed position, the decimal point is used, and up to 7 digits can be entered.
BEEP
In the closed position, the console beeper is enabled to signal various status and error
conditions. In the open position, the beeper is disabled.
CASH This switch must be closed if a cash drawer is present. It should open if a cash drawer is
not present.
DRWR In the open position, the cash drawer is active low. In the closed position, the cash
drawer is active high. Each cash drawer contains a sense switch to determine whether
the drawer is open or closed. If the sense switch is closed when the cash drawer is
closed, it is active low. If the sense switch is open when the cash drawer is closed, it is
active high.
DECP For switch 3-1. Indicates the character to be used for the decimal point. In the open
position, a period is used, in the closed position, a comma is used.
DEAD This switch enables the deadman timer. It should always be open.
SELF
In the open position, the console is in the normal mode of operation. In the closed
position, the console enters the self-test (diagnostic) mode.
OLD
In the closed position, the console accepts the old 2-position manager keyswitch. In the
open position, the console accepts the 4-position keyswitch.
QUIET In the open position, the off-hook alert beeps will occur at their standard intensity and
duration. In the closed position, the off-hook alert beeps will be quieter and shorter in
duration.
COLR In the open position, the pump status LED's will be red to signal the nozzle is off-hook but
the transaction is not yet approved and green for all other indications. In the closed
position, the colors are reversed.
ALRT
In the open position, the off-hook alert beep is enabled. In the closed position, the off-
hook beep is disabled.