Application of mc-mcr instruction, 2 details, Chapter 8 programming examples coding – KEYENCE Visual KV Series User Manual
Page 357

8.2 Details
3-333
1
8
Chapter 8 Programming Examples
Coding
➮ Refer to p. 3-86.
Application of MC-MCR instruction
■ Emergency stop circuit
When input relay 0000 is ON, 0500 turns ON for 1 s, then 0501 turns ON for 2 s,
and then 0502 turns ON for 3 s, repeatedly.
Once input relay 0000 turns OFF, 0500 turns ON when 0001 is ON, 0501 turns ON
when 0002 is ON, and 0502 turns ON when 0003 is ON.
Timing diagram
Coding
Ladder diagram
Line No.
Instruction
Operand
Line No.
Instruction
Operand
0000
LD
2008
0007
END
0001
EI
0008
INT
0000
0002
SET
2813
0009
LD
2002
0003
LD
0500
0010
SET
0500
0004
T000
#00010
0011
RETI
0005
LD
T000
0012
ENDH
0006
RES
0500
0000
0001
0002
0500
0501
0502
0003
0001
0002
0003
0004
0005
0006
0007
0008
0009
0010
0011
0012
0013
0015
0014
0016
0017
0018
0019
0020
0000
0000
1000
SET
RES
RES
1100
1101
1102
DIFU
1002 1002
STG
1100
1200
#00010 T000
JMP
1101
T000
MC
STG
1101
1201
#00020 T001
JMP
1102
T001
STG
1102
1202
#00030 T002
JMP
1100
T002
MCR
MC
1001
0001
0002
0003
MCR
1203
1204
1205
1200
1203
0500
1201
1204
1202
1205
0501
0502
END
ENDH
1000
1001
Line No.
Instruction
Operand
0000
LD
0000
0001
OUT
1000
0002
CON
0003
OUB
1001
0004
LD
0000
0005
DIFU
1002
0006
CON
0007
AND
1002
0008
SET
1100
0009
CON
0010
RES
1101
0011
CON
0012
RES
1102
0013
LD
1000
0014
MC
0015
STG
1100
0016
OUT
1200
0017
CON
0018
TMR
000 #00010
0019
CON
0020
AND
T000
0021
JMP
1101
0022
STG
1101
0023
OUT
1201
0024
CON
0025
TMR
001 #00020
0026
CON
0027
AND
T001
0028
JMP
1102
0029
STG
1102
0030
OUT
1202
0031
CON
0032
TMR
002 #00030
0033
CON
0034
AND
T002
0035
JMP
1100
0036
MCR
0037
LD
1001
0038
MC
0039
LD
0001
0040
OUT
1203
0041
LD
0002
0042
OUT
1204
0043
LD
0003
0044
OUT
1205
0045
MCR
0046
LD
1200
0047
OR
1203
0048
OUT
0500
0049
LD
1201
0050
OR
1204
0051
OUT
0501
0052
LD
1202
0053
OR
1205
0054
OUT
0502
0055
END
0056
ENDH
KVNKA Chap 08.p65
08.3.11, 0:12 PM
333