Visual kv series – KEYENCE Visual KV Series User Manual
Page 244

4.3 Setting and Operation of High-speed Counters
3-220
Visual KV
Series
4
Chapter 4 High-speed Counters
Fetching counts from encoder
Uses the double (x2) multiplication mode to fetch phase differential input from the
encoder.
The fetched data is output as BCD data. Phase differential input: 0004, 0006 BCD
output: 0600 to 0615 (4 digits)
Cording
● Initial setting
Special utility relays
•
Turn ON 2013 to reset the current value of CTH0 when CTC0 turns ON.
•
Turn ON 2113 and turn OFF 2114 to set the high-speed counter to double (x2)
multiplication mode.
•
Turn ON 2400 to enable the external reset.
The counter is reset at the rising edge of input 0008.
Note : The external reset input 0008 is set with hardware. Programming is not
necessary except for setting the external reset enable relay (2400 to ON).
2103
SET
2113
SET
2114
RES
CTH0
RES
2400
SET
2008
CTH0
LDA
TM00
STA
#00002
DIV
LDA
TBCD
0600
STA
2002 #00000
0000
CTH0
0004
2002
HSP
0004
HSP
0006
HSP
0008
END
ENDH
Initial setting
Line No.
Instruction
Operand
Line No.
Instruction
Operand
0000
LD
2008
0015
CTH
0 0004
0001
SET
2103
0016
LD
2002
0002
CON
0017
LDA
#0000
0003
SET
2113
0018
CON
0004
CON
0019
STA
TM00
0005
RES
2114
0020
CON
0006
CON
0021
LDA
CTH0
0007
RES
CTH0
0022
CON
0008
CON
0023
DIV
#00002
0009
SET
2400
0024
CON
0010
LD
2002
0025
TBCD
0011
HSP
0004
0026
CON
0012
HSP
0006
0027
STA
0600
0013
HSP
0008
0028
END
0014
LD
0000
0029
ENDH
➡
KVNKA Chap 04_1.p65
08.3.11, 0:06 PM
220