6.2 High-speed Counters
KV
-300
KV-10/80
3-281
1
6
Chapter 6 Interrupts, High-speed Counters, Positioning Control
CTH0 value
ON
OFF
CTC0
CTH0 value
ON
OFF
CTC0
CTC1
Special utility relay settings and output statuses
■ 16-bit high-speed counter (CTH0) and special utility relays (2103 to 2112)
By setting the special utility relays 2104 to 2112 at startup or changing these relays
during generation of clock pulse, you can select ON/OFF of output relay 0500 as
listed below.
These special utility relays also allow you to set the pulse cycle and pulse width
and enable or disable the direct output.
•
Special utility relay must be ON when clock pulse is generated.
•
Only one of relays 2104 to 2107 and one of relays 2108 to 2111 can be
turned ON. When two or more of the relays among each group are ON,
priority is given to the relay with the smallest No.
•
Turning OFF special utility relays 2104 and 2108 enable direct output.
Because these relays are factory-set to ON, be sure to set them to OFF.
•
ON/OFF status of special utility relays 2104 to 2112 is set using SET and
RES instructions or STA instruction.
•
Be sure to turn the special utility relay 2103 or 2112 ON to change the
pulse width. Turn ON 2103 or 2112 to change the pulse cycle.
•
Turn OFF 2105 to start clock pulse output. Turn ON 2105 to stop pulse
output.
•
When special utility relays 2104 and 2108 are turned ON while the direct
clock pulses are being output, the status of the output relay 0500 is output
and the pulses will be stopped.
■ Timing diagram of 0500 with special utility relay settings
•
ON-OFF ratio of 1:1
•
Variable pulse width
Settings of special utility relays
Settings of special utility relays
CAUTION
2103
ON
2112
OFF
2104
OFF
2108
OFF
2105
OFF
2109
OFF
2106
OFF
2110
OFF
2107
ON
2111
OFF
2103
ON
2112
OFF
2104
OFF
2108
OFF
2105
OFF
2109
ON
2106
ON
2110
OFF
2107
OFF
2111
OFF
Pulse status at CTH0 (current value) = CTC (preset value)
Comparator No.
Relay No.
Pulse status at ON.
CTC0
2103
Automatically clears current value of CTH0.
2104
Disables output to 0500.
2105
Outputs OFF to 0500
2106
Outputs ON to 0500.
2107
Inverts output to 0500.
CTC1
2112
Automatically clears current value of CTH0.
2108
Disables output to 0500.
2109
Outputs OFF to 0500
2110
Outputs ON to 0500.
2111
Inverts output to 0500.