1.3 Device Configuration
3-7
1
1
Chapter 1 Programming
1.3.2
Relay No.
The relay No. configuration is shown below.
Address No.
Address Nos. are assigned to basic units, input expansion units, output expansion
units, and I/O expansion units. Zero to 4 are assigned to input units, while 5 to 9 are
assigned to output units. Address Nos. assigned in a unit vary based on the number
of I/O terminals and the connection position of the unit.
* 2 to 4 in KV-40xx
■ Address No. assignment procedure
•
The address No. is represented as a number 0 to 9.
•
Address Nos. 0 to 4 are provided for inputs, while address Nos. 5 to 9 are pro-
vided for outputs.
1 2 5 1 5
Channel No.
Contact No.
(00 to 15)
Address No.
(Input: 0 to 4, output: 5 to 9)
Model
Address Nos.
KV-10xx
0, 5
Basic units
KV-16xx
0, 5
KV-24xx
0, 5
KV-40xx
0, 1, 5
kV-E4X
1 to 4*
Input expansion units
KV-E8X
1 to 4*
KV-E16X
1 to 4*
KV-E4R/E4T(P)
6 to 9
Output expansion units
KV-E8R/E8T(P)
6 to 9
KV-E16R/E16T(P)
6 to 9
I/O expansion units
KV-E4XR/E4XT(P)
1 to 4*, 6 to 9