1.3 Device Configuration

3-7

1

1

Chapter 1 Programming

1.3.2

Relay No.

The relay No. configuration is shown below.

Address No.

Address Nos. are assigned to basic units, input expansion units, output expansion
units, and I/O expansion units. Zero to 4 are assigned to input units, while 5 to 9 are
assigned to output units. Address Nos. assigned in a unit vary based on the number
of I/O terminals and the connection position of the unit.

* 2 to 4 in KV-40xx

Address No. assignment procedure

The address No. is represented as a number 0 to 9.

Address Nos. 0 to 4 are provided for inputs, while address Nos. 5 to 9 are pro-
vided for outputs.

1 2 5 1 5

Channel No.

Contact No.

(00 to 15)

Address No.

(Input: 0 to 4, output: 5 to 9)

Model

Address Nos.

KV-10xx

0, 5

Basic units

KV-16xx

0, 5

KV-24xx

0, 5

KV-40xx

0, 1, 5

kV-E4X

1 to 4*

Input expansion units

KV-E8X

1 to 4*

KV-E16X

1 to 4*

KV-E4R/E4T(P)

6 to 9

Output expansion units

KV-E8R/E8T(P)

6 to 9

KV-E16R/E16T(P)

6 to 9

I/O expansion units

KV-E4XR/E4XT(P)

1 to 4*, 6 to 9

KVNKA Chap 01P.p65

08.3.11, 11:49 AM

7