6.3 Positioning Control

KV

-300

KV-10/80

3-301

1

6

Chapter 6 Interrupts, High-speed Counters, Positioning Control

15000

17500

8000
2000

300

0

15000

Ramp-up/down control

When start switch 0002 is turned ON, 0500 outputs 100000 pulses under the
following conditions: start frequency 1 kHz, run frequency 5 kHz, and acceleration/
deceleration time 3 s.
Turn ON 0001 to decelerate and stop pulse output. When 0000 is turned ON, pulse
output is immediately stopped.

Application example of stepping motor control

Assume a program that can be controlled both automatically and manually.
In automatic mode, the system runs as shown in the chart below after 0000 is turned
ON.

In manual mode, the system goes forward while 0008 is ON and rearward while
0009 is ON. It returns to the origin when 0007 turns ON.
A pulse is output from 0500. Reverse the rotation direction by turning ON/OFF 0502.
The system is equipped with an origin sensor (0002), forward end limit (0006), and
rearward end limit (0004).

0002

DW

DW

DW

DW

DW

2008

EI

#01000 #05000 #03000 #00001 #34464 2310

0001

2308

END

INT

0000

2002

RES

2309

RET1

ENDH

DM9408 DM9409 DM9410 DM9411 DM9412

0001

0002

0003

0004

0005

0006

0007

0008

Enables interrupt when starting operation.
This is required to allow emergency stop
operation.

Sets parameters and simultaneously
starts pulse.

Decelerates and stops pulse.

Executes emergency stop sequence with
interrupt progaram.