KEYENCE Visual KV Series User Manual
Page 145

2.4 Instruction Details
1
2
3-121
Chapter 2 Instructions
ITVL
■ A/D data measurement
Turns ON output relay 0500 when the analog input from the KL-4AD to DM1600
(range: 1 to 5 V) exceeds +3 V. Turns ON output relay 0501 when the input is below
+2 V. Writes the average into DM0100.
Refer to the "KL-4AD/KL-2AD User’s Manual" for data memory settings for the KL-
4AD.
Coding
2008
2008
2008
2008
2003
0001
0002
1000
#01600
LDA
DM0000
STA
#02000
LDA
DM0001
STA
#01000
LDA
DM0002
STA
#00100
LDA
DM0003
STA
PLS
DM0000
PAUSE
1000
RES
ITVL
1001
1003
DM0100
STA
DM0007
LDA
0500
0501
Writes average into DM0100 every 100 measurement.
Measures contents of DM1600.
Sets max. setting value to +3 V (2000).
Sets min. setting value to +2 V (1000).
Sets number of averaging measurements to 100.
Pauses measurement when input relay 0001 turns ON.
Resets measurement when input relay 0002 turns ON.
0500 turns ON when measured value exceeds max. setting value.
0501 turns ON when measured value is below min. value.
Line No.
Instruction
Operand
Line No.
Instruction
Operand
0000
LD
2008
0014
CON
0001
LDA
#01600
0015
STA
DM0003
0002
CON
0016
LD
2003
0003
STA
DM0000
0017
LD
0001
0004
LD
2008
0018
LD
0002
0005
LDA
#02000
0019
ITVL
DM0000 1000
0006
CON
0020
LD
1000
0007
STA
DM0001
0021
OUT
0500
0008
LD
2008
0022
LD
1001
0009
LDA
#01000
0023
OUT
0501
0010
CON
0024
LD
1003
0011
STA
DM0002
0025
LDA
DM0007
0012
LD
2008
0026
STA
DM0100
0013
LDA
#00100
KVNKA Chap 02_4bP.p65
08.3.11, 0:00 PM
121