4.7 Examples of Direct Clock Pulse Output

3-248

Visual KV

Series

4

Chapter 4 High-speed Counters

0000

0000

2205

RES

2205

SET

0000

0000

RES

KEEP

2205

SET

Coding

Note :When the input enable relay for the high-speed counter is used to start/stop
the clock pulse, the response is delayed by a maximum of one scan when output
starts. The response is also delayed by a maximum of one scan when the output
stops.

Tips

Use special utility relay 2205 to control (enable/disable) the clock pulse output by
external inputs.

Use the SET-RES pair or KEEP instruction to turn special utility relay 2205 ON/
OFF.
With this setting, the clock pulse is always turned OFF when it starts as well as
stops.

When either of the following programs is added to the example on the previous
page, the clock pulse is output from 0501 only when 0000 is ON.

When SET-RES instructions are used

When KEEP instruction is used

You can change the period (frequency) of the clock pulse by changing CTC2
preset value using LDA and STA instructions.
To change the period of the clock pulse, refer to "4.3.4 Count Input Method" on
page 3-212.

Line No.

Instruction

Operand

Line No.

Instruction

Operand

0000

LD

2008

0012

SET

2209

0001

MPS

0013

CON

0002

SET

2203

0014

RES

2210

0003

CON

0015

CON

0004

RES

2204

0016

RES

2211

0005

CON

0017

CON

0006

SET

2205

0018

RES

CTH1

0007

CON

0019

LD

2002

0008

RES

2207

0020

CTH

1 2201

0009

MPP

0021

CTC

2 #00050

0010

RES

2208

0022

CTC

3 #00020

0011

CON

KVNKA Chap 04_2.p65

08.3.11, 0:08 PM

248