Single-axis controllers, For the selection ”mode 1 – Lenze 9400 Manual User Manual
Page 64
Single-axis controllers
Rated data (devices for 400/500V mains)
Operation at rated mains voltage 500 V
4
64
EDS94SPP101 EN 7.1
For the selection ”Mode 1“:
Output currents [A] at switching frequency
2 kHz
Type
I
aN2
I
aNhc
I
aMhc
I
aMre
E94ASxE1454
145
160
218
145
E94ASxE1724
172
195
258
180
E94ASxE2024
202
240
303
226
E94ASxE2454
245
302
368
275
E94ASxE2924
292
361
438
330
E94ASxE3664
366
443
549
415
E94ASxE4604
460
550
690
522
E94ASxE5724
572
610
858
550
E94ASxE6354
635
678
953
610
E94ASxE6954
695
730
1043
653
I
aN2
Rated value of continuous output current at a frequency of ≥ 0 Hz
(standard operation)
I
aNhc
Increased continuous output current at a frequency of ≥ 0 Hz
I
aMhc
Maximum output current (overload current)
z
Periodic load change of 10 s with I
aMhc
and recovery time of 50 s with I
aMre
I
aMre
Maximum output current during the recovery time of 50 s
Sinusoidal filter assignments changed for this operating mode:
Motor cable lengths when sinusoidal filters and line filters are used
Compliance with the EMC protection requirement C2
Type
Setting C01199
Sinusoidal filter
shielded
unshielded
Switching
frequency
E94ASxE2924
”Mode 1”
EZS3-480A200
150 m
- m
2 kHz
or
4 kHz
The selection ”Mode 2“ is only permissible for mains voltages ≤ 440 V.