3 rated data, 1 overview, Overview – Lenze 9400 Manual User Manual
Page 163: Multi-axis controllers
Multi-axis controllers
Rated data
Overview
5
163
EDS94SPP101 EN 7.1
5.3
Rated data
The E94AMxExxx4 devices can be used in the voltage range of 260 ... 775 V DC.
Note!
To ensure a faultless operation of the devices the code C00173 must be set
according to the mains voltage connected.
Emergency operation
Operation of the E94ASxxxx4 devices with an emergency voltage supply at +UG, -UG, is
possible from U
DC
≥
260 V. The settings in C00173 and C00174 are to be adapted
accordingly.
Operation of the E94AMxxxx4 devices with an emergency voltage supply at +UG, -UG, is
possible with U
DC
≤
260 V. The settings in C00173 and C00174 are to be adapted
accordingly. A 24-V supply at X2 is required.
5.3.1
Overview
Input data
Voltage
Frequency
Current [A]
Number of
phases
[V]
[Hz]
max. +45 °C c
max. +55 °C c
E94AMxE0024
325/565/705
0 ( DC)
2.6/2.6/2.3
2.0/2.0/1.7
2
E94AMxE0034
325/565/705
0 ( DC)
4.3/4.3/3.8
3.2/3.2/2.9
2
E94AMxE0044
325/565/705
0 ( DC)
6.7/6.7/5.9
5.0/5.0/4.4
2
E94AMxE0074
325/565/705
0 ( DC)
12.1/12.1/10.6
9.1/9.1/8.0
2
E94AMxE0094
325/565/705
0 ( DC)
15.4/15.4/13.5
11.6/11.6/10.1
2
E94AMxE0134
325/565/705
0 ( DC)
20.6/20.6/18.0
15.5/15.5/13.5
2
E94AMxE0174
325/565/705
0 ( DC)
25.7/25.7/22.5
19.3/19.3/16.9
2
E94AMxE0244
325/565/705
0 ( DC)
35.5/35.5/31.1
26.3/26.3/23.3
2
E94AMxE0324
325/565/705
0 ( DC)
48.0/48.0/38.9
36.0/36.0/29.1
2
c
Temperature in the control cabinet