Accessories (overview), Connection plan – Lenze 9400 Manual User Manual
Page 451
Accessories (overview)
Motor holding brake control modules
Motor holding brake control module E94AZHY0025
9
451
EDS94SPP101 EN 7.1
Installation steps
1. Plug the motor brake control module onto the terminals of the standard device.
– Ensure that both clips snap into the slots of the standard device!
2. Check that the motor brake control module is securely connected.
Terminal data
Terminal X107
Labelling
Description
Connection of the motor holding brake:
BD1
BD2
+ (Lenze: WH)
- (Lenze: BN)
E94AZHY0025: 205 V DC, max. 0.75 A
Ensure correct polarity!
SSP94A6107
L1
L2/N
Supply voltage of the motor holding brake
Terminal data
Conductor cross-section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb-in]
Flexible
0.5 ... 2.5
20 ... 12
Spring terminal
With wire end
ferrule
Stripping length or contact length: 8 mm
Connection plan
L1
L2
L3
N
PE
F10
BD1
BD1
L1
L3
PE
L2
L1
L3
PE
L2
BD2
BD2
M
3~
M
3~
£ 2.5 mm²
E94APNExxx4
E94ASxExxx4
E94AMxExxx4
E94AZHY0025
E94AZHY0025
L1
L2/N
L2/N L1
"
"
"
"
X107
X107
E94AZH016
F10
Observe the cable protection standards for fuse dimensioning!
HF shield termination through large-surface PE connection