3 dc-power requirements, Dc-power requirements, Dc-bus operation – Lenze 9400 Manual User Manual
Page 323: Rated data dc-power requirements

DC-bus operation
Rated data
DC-power requirements
8
323
EDS94SPP101 EN 7.1
8.4.3
DC-power requirements
Use the below tables to determine the power requirements of the devices used in the DC
bus and the device-dependent power loss for the rated mains voltage U
Lr
.
Power requirements P
ar
[W] with rated current
Type
U
Lr
= 230 V
U
Lr
= 400 V
U
Lr
= 500 V
Multi Drives
E94AMxE0024
500
900
1000
E94AMxE0034
900
1600
1700
E94AMxE0044
1400
2500
2700
E94AMxE0074
2500
4400
4800
E94AMxE0094
3300
5800
6400
E94AMxE0134
4700
8100
8900
E94AMxE0174
5900
10300
11200
E94AMxE0244
8400
14700
16100
E94AMxE0324
11500
20000
20200
Single Drives
E94ASxE0024
500
900
1000
E94ASxE0034
900
1600
1700
E94ASxE0044
1400
2500
2700
E94ASxE0074
2500
4400
4800
E94ASxE0134
4700
8100
8900
E94ASxE0174
5900
10300
11200
E94ASxE0244
8400
14700
16100
E94ASxE0324
11500
20000
21800
E94ASxE0474
16900
29300
32000
E94ASxE0594
19000
33100
40200
E94ASxE0864
30800
53600
58700
E94ASxE1044
37300
64800
70900
E94ASxE1454
-
90000
113000
E94ASxE1724
-
107000
134000
E94ASxE2024
-
126000
157000
E94ASxE2454
-
153000
191000
E94ASxE2924
-
182000
228000
E94ASxE3664
-
228000
285000
E94ASxE4604
-
287000
359000
E94ASxE5724
-
357000
446000
E94ASxE6354
-
396000
495000
E94ASxE6954
-
433000
542000
Tab. 8-5