Single-axis controllers, General data and operating conditions, General electrical data – Lenze 9400 Manual User Manual
Page 41
Single-axis controllers
General data and operating conditions
4
41
EDS94SPP101 EN 7.1
General electrical data
Motor cable requirements
Capacitance per unit length
≤
2.5 mm
2
/AWG 14
C
Core/core
/C
Core/shield
< 75/150 pF/m
≥
4 mm
2
/AWG 12
C
Core/core
/C
Core/shield
< 150/300 pF/m
Electric strength
VDE 0250-1
U
0
/U
=
0.6/1.0 kV
(U
0
= r.m.s. value of external conductor to PE,
U = r.m.s. value of external conductor to external conductor)
UL
U ≥ 600 V
(U = r.m.s. value of external conductor to external conductor)
Maximum motor and feedback cable lengths
(for shielded motor cable with rated mains voltage)
Type
Device size
[m]
E94AMxE0024
E94AMxE0034
E94AMxE0044
1
50
E94ASxE0024
E94ASxE0034
E94AMxE0074
E94AMxE0094
2
100
E94ASxE0044
E94ASxE0074
E94AMxE0134
E94AMxE0174
E94AMxE0244
3
100
E94AMxE0324
3
100
E94ASxE0134
E94ASxE0174
E94ASxE0244
3
100
E94ASxE0324
E94ASxE0474
E94ASxE0594
6
100
E94ASxE0864
E94ASxE1044
7
100
E94ASxE1454
8S
150
E94ASxE1724
E94ASxE2024
8
150
E94ASxE2454
E94ASxE2924
E94ASxE3664
9
150
E94ASxE4604
E94ASxE5724
E94ASxE6354
E94ASxE6954
10
150
If EMC conditions must be met, the permissible cable lengths can be reduced.
Tab. 4-1