Power supply modules – Lenze 9400 Manual User Manual
Page 231
Power supply modules
Device description
Devices in the range 10 ... 36 A (4 ... 18 kW)
6
231
EDS94SPP101 EN 7.1
Standard device
Pos.
Description
X11
24 V supply
X12
4 digital outputs
1 digital input
Nameplate, retractable
Setting of mains voltage/brake chopper threshold
Upper cap
The LED display enables fast indication of several operating states.
LED
Labelling
Colour
Description
-
-
-
OVERHEAT
Red
Overtemperature
MAINS
Green
Mains voltage OK
BRCHOP FAIL
Red
Short circuit on brake chopper
24 V
Green
24 V supply voltage OK
SSP94LED21
BRCHOP ON
Yellow
Brake chopper active
Pos.
Symbol
Description
Long discharge time: All power terminals carry hazardous voltages for at
least 3 minutes after mains disconnection!
High discharge current: Fixed installation and PE connection to EN 61800-5-1
required!
Electrostatic sensitive devices: Before working on the device, personnel must
ensure that they are free of electrostatic charge!
Installation backplane
Pos.
Description
X111
Mains (supply from above, e.g. from top filters)
DC-bus voltage (compatible with 9300 series)
X112
Mains (supply from below, e.g. from built-on filter)
External brake resistor
X109
DC-bus busbar +
Direct connection of
9400 axis modules,
device sizes 1 ... 3
X110
DC busbar -
EMC shield clamp