Dc-bus operation, Rated data dc fuses – Lenze 9400 Manual User Manual
Page 326
DC-bus operation
Rated data
DC fuses
8
326
EDS94SPP101 EN 7.1
Fuse the individual +UG/-UG cables to protect the DC-bus connection. The DC-bus
connection is protected against damage through a DC earth fault or short circuit in a
device.
Controller/DC fuse assignment
Type
Rated value
Type
Size
Number per
[A]
(SIBA)
[mm] or size
+UG/-UG
Multi Drives
E94AMxE0024
E94AMxE0034
E94AMxE0044
20
EFSGR0200AYHz
14 x 51
1
EFSGR0200AYIz
22 x 58
E94AMxE0074
E94AMxE0094
32
EFSGR0320AYHz
14 x 51
EFSGR0320AYIz
22 x 58
E94AMxE0134
E94AMxE0174
63
EFSGR0630AYIz
22 x 58
E94AMxE0244
E94AMxE0324
100
EFSGR1000AYIz
22 x 58
Single Drives
E94ASxE0024
E94ASxE0034
16
EFSGR0200AYHz
14 x 51
1
EFSGR0200AYIz
22 x 58
E94ASxE0044
E94ASxE0074
32
EFSGR0320AYHz
14 x 51
EFSGR0320AYIz
22 x 58
E94ASxE0134
E94ASxE0174
63
EFSGR0630AYIz
22 x 58
E94ASxE0244
E94ASxE0324
E94ASxE0474
100
EFSGR1000AYIz
22 x 58
EFSGR1000ANVN
NH1
E94ASxE0594
E94ASxE0864
200
EFSGR2000ANVN
NH1
E94ASxE1044
250
EFSGR2500ANWN
NH2
E94ASxE1454
350
EFSGR3500ANWN
NH2
E94ASxE1724
E94ASxE2024
400
EFSGR4000ANWN
NH2
E94ASxE2454
500
EFSGR5000ANWN
NH2
E94ASxE2924
350
EFSGR3500ANWN
NH2
2 (in parallel)
E94ASxE3664
400
EFSGR4000ANWN
NH2
E94ASxE4604
500
EFSGR5000ANWN
NH2
E94ASxE5724
400
EFSGR4000ANWN
NH2
3 (in parallel)
E94ASxE6354
500
EFSGR5000ANWN
NH2
E94ASxE6954
Tab. 8-7
z