Power supply modules, Internal brake chopper data – Lenze 9400 Manual User Manual
Page 220

Power supply modules
Rated data (devices for 400/500V mains)
Operation at rated mains voltage 230 V
6
220
EDS94SPP101 EN 7.1
Output current and output power
100 %
5-s cycle
3-min cycle
Type
I
DC
[A]
P
DC
[kW]
I
DC
[A]
P
DC
[kW]
I
DC
[A]
P
DC
[kW]
E94APNE0104
10
2.1
40
8.4
15
3.2
E94APNE0104
+ E94AZMP0084
10
2.8
40
11.2
15
4.2
E94APNE0364
36
7.5
108
22.5
54
11.3
E94APNE0364
+ E94AZMP0294
36
10.1
108
30.3
54
15.5
E94APNE1004
100
20.8
200
62.4
150
31.2
E94APNE1004
+ E94AZMP0824
100
27.9
200
83.7
150
41.9
E94APNE2454
245
51
368
153
368
76.5
E94APNE2454
+ E94AZMP2004
245
68.5
368
206
368
103
100 %
Permanent rated values
5-s cycle
Cycle for the second-range
(0.5 s overload/4.5 s recovery time with 75 % of the permanent rated value)
3-min cycle
Cycle for the minute-range
(60 s overload/120 s recovery time with 75 % of the permanent rated value)
Internal brake chopper data
R
Bmin
[Ω]
I
BRmax
[A]
P
BRmax
[kW]
I
BRd
[A]
P
Bd
[kW]
t
Z
[s]
t
on
[s]
t
fp
[s]
Type
E94APNE0104
18.0
21.7
8.5
7.9
1.1
4.3
0.5
0.5
E94APNE0364
6.0
65.0
25.4
29.1
5.1
3.0
0.5
0.5
E94APNE1004
2.5
156
60.8
62.7
9.8
3.6
0.5
0.5
E94APNE2454
1.4
279
109
112
17.5
3.6
0.5
0.5
R
Bmin
Minimum brake resistance, nominal value ±10 %
I
BRmax
Peak current
P
BRmax
Peak braking power
I
BRd
Continuous current RMS - important for the dimensioning of the cables
P
Bd
Continuous braking power
t
Z
Cycle time, periodic load change with running time and recovery time
t
on
Running time
t
Z
- t
on
Recovery time
t
fp
Maximum running time without initial load and compliance with the recovery
time