Accessories (overview)
Motor holding brake control modules
Motor holding brake control module E94AZHY0101
9
430
EDS94SPP101 EN 7.1
Standards
Conformity and approval
Conformity
CE
2006/95/EC
Low-Voltage Directive
Approval
UR
UL 508C
Industrial Control Equipment Recognised
(file no. E132659) for USA
Protection of persons and equipment
Enclosure
EN 60529
IP00
Protective measures
Against short circuit
EMC
Noise emission
EN 61800-3
Conducted, category C2.
Noise immunity
EN 61800-3
Burst on mains cable:
2 kV/5 kHz
Burst on control cable:
2 kV/5 kHz
Surge on mains cable:
1 kV (1.2 μs/50 μs;
phase - phase)
2 kV (1.2 μs/50 μs; phase - PE)
Operating conditions
The operating conditions correspond to the operating conditions for the standard device
to which the DC-feeding point is connected.
Environmental conditions
Climate
Storage
IEC/EN 60721-3-1
1K3 (-25 ... +60 °C)
Transport
IEC/EN 60721-3-2
2K3 (-25 ... +70 °C)
Operation
IEC/EN 60721-3-3
3K3 (-10 ... +55 °C)
Current derating at +45 ... +55 °C:
Device size 1 ... 7: 2.5 %/°C
Device size 8S ... 10: 1 %/°C
Site altitude
0 ... 4000 m amsl
1000 ... 4000 m amsl: current derating of 5 %/1000 m
Pollution
EN 61800-5-1
Degree of pollution 2
Vibration resistance
(9.81 m/s
2
= 1 g)
Transport
IEC/EN 60721-3-2
2M2
EN 61800-2
2 ... 9 Hz: amplitude 3.5 mm
10 ... 200 Hz: acceleration resistant up to 10 m/s
2
200 ... 500 Hz: acceleration resistant up to 15 m/s
2
Operation
Germanischer Lloyd
5 ... 13.2 Hz: amplitude ±1 mm
13.2 ... 100 Hz: acceleration resistant up to 0.7 g
IEC/EN 60068-2-6
10 ... 57 Hz: amplitude 0.075 mm
57 ... 150 Hz: acceleration resistant up to 1 g