Accessories (overview), Filters sinusoidal filter 180 a, General data – Lenze 9400 Manual User Manual
Page 554
Accessories (overview)
Filters
Sinusoidal filter 180 ... 480 A
9
553
EDS94SPP101 EN 7.1
General data
Conformity and approval
Conformity
CE
2006/95/EC
Low-Voltage Directive
Protection of persons and equipment
Degree of protection
EN 60529
IP00
Earth leakage current
IEC/EN 61800-5-1
> 3.5 mA
Observe stipulations and safety
instructions!
Insulation resistance
IEC/EN 61800-5-1
< 2000 m site altitude: overvoltage category III
> 2000 m site altitude: overvoltage category II
Environmental conditions
Climate
Storage
IEC/EN 60721-3-1
1K3 (-25 ... +60 °C)
Transport
IEC/EN 60721-3-2
2K3 (-25 ... +70 °C)
Operation
IEC/EN 60721-3-3
3K3 (-10 ... +55 °C)
Current derating at +40 ... +55 °C: 2.5 %/°C
Site altitude
0 ... 4000 m amsl
1000 ... 4000 m amsl: Current derating 5 %/1000 m
Pollution
EN 61800-5-1
Degree of pollution 2
Vibration resistance
(9.81 m/s
2
= 1 g)
Transport
IEC/EN 60721-3-2
2M2
EN 61800-2
2 ... 9 Hz: Amplitude 3.5 mm
10 ... 200 Hz: Acceleration resistant up to 10 m/s
2
200 ... 500 Hz: Acceleration resistant up to 15 m/s
2
Operation
Germanischer Lloyd
5 ... 13.2 Hz: Amplitude ±1 mm
13.2 ... 100 Hz: Acceleration resistant up to 0.7 g
IEC/EN 60068-2-6
10 ... 57 Hz: Amplitude 0.075 mm
57 ... 150 Hz: Acceleration resistant up to 10 m/s
2
Mounting conditions
Mounting place
In the control cabinet
Mounting position
Vertical, fixing bracket below
Free space
100 mm to the side and above