Accessories (overview)
Communication modules
PROFIBUS
9
379
EDS94SPP101 EN 7.1
External voltage supply
Note!
Always use a separate power supply unit in every control cabinet and safely
separate it according to EN 61800-5-1 (”SELV”/”PELV”) in the case of external
voltage supply and larger distances between the control cabinets.
The external voltage supply of the communication module is required if communication
via the bus system is to continue in the event of a power supply failure of the standard
device.
ƒ
The external voltage supply of the communication module is required if
communication is to continue when the power supply of the standard device fails.
ƒ
Access to parameters of a standard device disconnected from the mains is not
possible.
ƒ
The external voltage supply is effected via the 2-pole plug connector.
Connection of the 2-pin plug connector (X200):
Designation
Explanation
+
U = 24 V DC (20.4 V - 0 % ... 28.8 V + 0 %)
I = 130 mA
-
Reference potential for external voltage supply
Connect the communication module to the bus system according to the description
( 380).
Terminal data
Area
Values
Electrical connection
Plug connector with screw connection
Possible connections
rigid:
1.5 mm
2
(AWG 16)
flexible:
without wire end ferrule
1.5 mm
2
(AWG 16)
with wire end ferrule, without plastic sleeve
1.5 mm
2
(AWG 16)
with wire end ferrule, with plastic sleeve
1.5 mm
2
(AWG 16)
Tightening torque
0.5 ... 0.6 Nm (4.4 ... 5.3 lb-in)
Stripping length
6 mm