Page 107: Wiring devices in the range 2 a (0.37 kw)
Single-axis controllers
Wiring
Devices in the range 2 ... 24 A (0.37 ... 11 kW)
4
107
EDS94SPP101 EN 7.1
4.6.4
Devices in the range 2 ... 24 A (0.37 ... 11 kW)
L3
N
PE
L1
L2
F1...F3
Z1
F4
K1
K1
K1
L1
L2
L3
E94ASxExxxx
X100
-UG
O
I
RFR
+UG
Rb2
Rb1
R
B
R
B
U V W
X105
BD1
+
BD2
-
X107
X5
T1
GI
RFR
T2
X106
M
3~
R
Y
J
J
2
7
. . .
E94AZPxxxxx
+
-
EYF...
+
-
X7
X3
+
-
A1-
A1+
+
+
SSP94PSP01
Fig. 4-22
Basic circuit diagram of the drive system
E94ASxExxxx
9400 Single Drive servo axis module
E94AZPxxxxx
Installation backplane
F1 ... F4
Fuses
Z1
Mains filter/RFI filter (optional)
HF shield termination through large-surface connection to functional earth
EYF...
System cable for resolver feedback
RFR
Controller enable
K1
Mains contactor
R
Resolver
RB
Brake resistor
Y
Motor holding brake (connected to optional motor brake control)
c
Speed setpoint selection via analog input 1 (-10 ... 0 ... +10 V)
d
Voltage source for the motor holding brake
e
24-V voltage source for the digital inputs according to IEC 61131-2
Tip!
Complete the wiring of the installation backplane before plugging in the
standard device. The upper terminals of the installation backplane cannot be
connected with a plugged-in standard device.