Power supply modules, Internal brake chopper data – Lenze 9400 Manual User Manual
Page 224
Power supply modules
Rated data (devices for 400/500V mains)
Operation at a rated mains voltage of 500 V
6
224
EDS94SPP101 EN 7.1
Output current and output power
100 %
5-s cycle
3-min cycle
Type
I
DC
[A]
P
DC
[kW]
I
DC
[A]
P
DC
[kW]
I
DC
[A]
P
DC
[kW]
E94APNE0104
10
4.5
40
18.0
15
6.8
E94APNE0104
+ E94AZMP0084
10
6.1
40
24.4
15
9.2
E94APNE0364
36
16.3
108
48.9
54
24.5
E94APNE0364
+ E94AZMP0294
36
21.9
108
65.7
54
32.9
E94APNE1004
100
45.2
200
136
150
67.8
E94APNE100
+ E94AZMP0824
100
60.8
200
182
150
91.2
E94APNE2454
245
111
368
333
368
167
E94APNE2454
+ E94AZMP2004
245
149
368
447
368
224
100 %
Permanent rated values
5-s cycle
Cycle for the second-range
(0.5 s overload/4.5 s recovery time with 75 % of the permanent rated value)
3-min cycle
Cycle for the minute-range
(60 s overload/120 s recovery time with 75 % of the permanent rated value)
Internal brake chopper data
R
Bmin
[Ω]
I
BRmax
[A]
P
BRmax
[kW]
I
BRd
[A]
P
Bd
[kW]
t
Z
[s]
t
on
[s]
t
fp
[s]
Type
E94APNE0104
27.0
29.3
23.1
10.6
3.0
4.3
0.5
0.5
E94APNE0364
12.0
65.8
52.0
29.4
10.4
3.0
0.5
0.5
E94APNE1004
5.0
158
125
63.5
20.1
3.6
0.5
0.5
E94APNE2454
2.8
282
223
113
36.0
3.6
0.5
0.5
R
Bmin
Minimum brake resistance, nominal value ±10 %
I
BRmax
Peak current
P
BRmax
Peak braking power
I
BRd
Continuous current RMS - important for the dimensioning of the cables
P
Bd
Continuous braking power
t
Z
Cycle time, periodic load change with running time and recovery time
t
on
Running time
t
Z
- t
on
Recovery time
t
fp
Maximum running time without initial load and compliance with the recovery
time