Accessories (overview)
Communication modules
PROFINET
9
383
EDS94SPP101 EN 7.1
Connections
Pos.
Description
X240
Connection for the external supply of the communication module
Design: Plug connector with spring connection, 2-pole
X241
PROFINET connections
Design: RJ45 socket according to IEC 60603-7
X242
Displays
LED
Description
Pos.
Colour
Condition
MS
Green
Blinking
The communication module is supplied with voltage but has no
connection to the basic device (basic device is either switched off, in the
initialisation phase, or not available).
On
The communication module is supplied with voltage and has a
connection to the basic device.
ME
Red
On
There is an error in the area of the communication module.
BS
Green
Off
The PROFINET module is not active at the fieldbus.
Blinking
The PROFINET module is in the ”Data_Exchange” state.
BE
Red
On
Bus error/trouble is active, e.g. the Ethernet cable is unplugged. (The LED
is blinking in parallel to the BS LED.)
DE
Red
On
The communication module is not accepted by the basic device (see
notes in the instructions for the basic device)or the standard device is not
active.
Signalling on the connection X241/X242:
-
yellow
on/blinking
Data is exchanged via PROFINET.
-
Green
On
PROFINET connection is available.