4 operation at rated mains voltage 500 v, Operation at rated mains voltage 500 v, Single-axis controllers – Lenze 9400 Manual User Manual
Page 60: Device size 7
Single-axis controllers
Rated data (devices for 400/500V mains)
Operation at rated mains voltage 500 V
4
60
EDS94SPP101 EN 7.1
4.3.4
Operation at rated mains voltage 500 V
Device size 1 ... 6
Basis of the data
Mains
Voltage
Voltage range
Frequency range
U
LN
[V]
U
LN
[V]
f [Hz]
3/PE AC
500
400 - 0 % ... 550 + 0 %
45 - 0 % ... 65 + 0 %
2/PE DC
705
565 - 0 % ... 775 + 0 %
-
Mains current at I
aN
Output power
Motor power
(typical)
with external
mains choke
without external
mains choke
U, V, W
4 pol. ASM
Type
I
LN
[A]
I
LN
[A]
S
aN
[kVA]
P
aN
[kW]
P
aN
[hp]
E94ASxE0024
1.3
1.8
1.0
0.37
0.5
E94ASxE0034
2.2
3.1
1.7
0.75
1
E94ASxE0044
3.4
4.8
2.7
1.5
2
E94ASxE0074
6.1
8.7
4.8
3
4
E94ASxE0134
10.5
14.7
8.9
5.5
7.5
E94ASxE0174
13.1
18.4
11.3
7.5
10
E94ASxE0244
17.9
25.4
16.0
11
15
E94ASxE0324
-
26.0
21.8
15
20
E94ASxE0474
-
37.6
32.1
22
29
E94ASxE0594
-
47.0
40.2
30
40
Device size 7
Basis of the data
Mains
Voltage
Voltage range
Frequency range
U
LN
[V]
U
LN
[V]
f [Hz]
3/PE AC
500
400 - 0 % ... 550 + 0 %
45 - 0 % ... 65 + 0 %
Mains current at I
aN
Output power
Motor power
(typical)
with external
mains choke
without external
mains choke
U, V, W
4 pol. ASM
Type
I
LN
[A]
I
LN
[A]
S
aN
[kVA]
P
aN
[kW]
P
aN
[hp]
E94AsxE0864
-
70.0
58.6
45
60
E94ASxE1044
-
84.0
70.9
55
73