Power supply modules – Lenze 9400 Manual User Manual
Page 228
Power supply modules
Rated data (devices for 400/500V mains)
Mains filters for power supply modules
6
228
EDS94SPP101 EN 7.1
With different motor cable lengths, per axis at least 25 % of the longest cable must be
considered when calculating the total motor cable length.
Example: 1
Motor cable length l
mot
[m]
Axis
Actual
value
min. 25 % of the longest cable
To be considered
1
6
0.25 * 20 = 5
6
2 ... 4
3 * 10
3 * 10
5
20
Õ
20
Total
56
max. permissible for 5 axes: ∑< 60
56
EMC class C2 will be complied with.
;
Example: 2
Motor cable length l
mot
[m]
Axis
Actual
value
min. 25 % of the longest cable
To be considered
1 ... 4
4 * 5
0.25 * 40 = 10
4 * 10
5
40
Õ
20
Total
60
max. permissible for 5 axes: ∑< 60
80
EMC class C2 will not be complied with.
:
Other interference factors
Compliance of EMC class C2 may also be interfered with by other factors:
ƒ
Distribution of axis modules over several control cabinets
ƒ
No use of Lenze system cables or cables with the same specifications
ƒ
Poor connection of motor cable shields
ƒ
Motor cable interruptions
ƒ
Other interference sources (e.g. switched-mode power supplies)
ƒ
Synchronous switching of limit switches