Single-axis controllers, For the selection ”mode 2 – Lenze 9400 Manual User Manual
Page 58
Single-axis controllers
Rated data (devices for 400/500V mains)
Operation at rated mains voltage 400 V
4
58
EDS94SPP101 EN 7.1
For the selection ”Mode 2“:
Output currents [A] at switching frequency
2 kHz
Type
I
aN2
I
aNhc
I
aMhc
I
aMre
E94ASxE1454
145
177
195
168
E94ASxE1724
172
212
233
201
E94ASxE2024
202
260
286
247
E94ASxE2454
245
315
347
299
E94ASxE2924
292
395
434
375
E94ASxE3664
366
480
528
456
E94ASxE4604
460
600
660
570
E94ASxE5724
572
658
724
625
E94ASxE6354
635
745
820
708
E94ASxE6954
695
800
880
760
I
aN2
Rated value of continuous output current at a frequency of ≥ 0 Hz
(standard operation)
I
aNhc
Increased continuous output current at a frequency of ≥ 0 Hz
I
aMhc
Maximum output current (overload current)
z
Periodic load change of 60 s with I
aMhc
and recovery time of 120 s with I
aMre
I
aMre
Maximum output current during the recovery time
Sinusoidal filter assignments changed for this operating mode:
Motor cable lengths when sinusoidal filters and line filters are used
Compliance with the EMC protection requirement C2
Type
Setting C01199
Sinusoidal filter
shielded
unshielded
Switching
frequency
E94ASxE2024
”Mode 2”
EZS3-350A200
150 m
- m
2 kHz
or
4 kHz
E94ASxE2924
EZS3-480A200
E94ASxE4604
EZS3-480A200
(2 in parallel)